Popular 'pinpoint tests' will often not help you get out of those troubling diagnostic dilemmas.
“Replace with known good PCM, then re-test.” How many times have we, much to our dismay, reached this step in any kind of pinpoint test, or trouble tree, as they are sometimes referred to? How many times have we followed this instruction, only to find out, much to our horror, that the “known good PCM” that we just installed didn’t solve our diagnostic dilemma? How many times have we asked ourselves, “Now what should we do?”
I once heard an instructor of mine years ago state, “You know why they are called trouble trees? Because they get you into trouble!” Over the years, I have had my fair share of “getting into trouble” situations by using a trouble tree, either through my own fault or some kind of error in the trouble tree instructions.
Let’s discuss a few methods that can be used to minimize the chances of the above scenario occurring. Since I prefer to use the term “pinpoint test” — the word trouble has such a negative connotation for me — let’s call them “Pinpoint Test Diagnostic Tips.”
Most pinpoint tests usually consist of an introductory section, where fault code description, wiring diagrams, and circuit descriptions of the components involved with the particular fault code that was retrieved are located. Some even list the particular parameters required to set that particular fault code. Whenever you resort to actually using a pinpoint test, you should thoroughly understand this section before proceeding to the actual test section itself.
The main body of the pinpoint test contains the particular test steps for diagnosing a particular fault code. Most pinpoint tests have a header box at the beginning of each step that will give a description of what is actually being checked at that step. An example of this would be the following: “Check Circuit XXX for a short to ground.” Immediately following this, within the same step and just below the header box, will be the test procedure(s) for checking to determine if “Circuit XXX” is shorted to ground.
It is very important to determine that the testing procedure shown is a valid method of checking for what is listed in the header. For instance, if the test instructions state to check the circuit with an ohmmeter, but the instructions also tell you to turn the key on before going any further, you immediately know that this is incorrect. It becomes your responsibility to determine the proper means of testing that circuit. Blindly following any pinpoint test instruction without determining if the instructions are correct will definitely get you “into trouble.”
Over the course of my career, I have lost count of the number of mistakes I have found in pinpoint tests, which is why I try to avoid using them. So, you ask, what other diagnostic method should we use?
My preference is to have a thorough understanding of electricity and electronics, the correct definition of the fault code retrieved along with the parameters for setting that code, and a wiring diagram. My diagnostic method of choice is what I refer to as “OCI,” an acronym for “Opposite Code Inducement.”
Take a look at the wiring diagram shown below. This is a very oversimplified schematic representation of the circuits involved in most two-wire sensor circuits. The small V inside the PCM represents the PCM internal voltmeter. In actuality, there is a lot more going on electronically inside the PCM than is depicted in the diagram. That said, for the purposes of diagnostics, it is all you really need to diagnose most fault codes that are hard faults, otherwise known as “on demand” codes (intermittent codes, often referred to as “memory” codes or “historical” codes, are another discussion altogether). The designation VREF represents the reference voltage circuit and the designation SIG RTN represents the signal return circuit. As represented by the electrical symbol in the diagram, the sensor in the circuit is a variable resistance sensor, for example, an engine coolant temperature sensor.
Now, let’s put OCI to work. Suppose a fault code is retrieved for a high sensor input voltage. In this particular instance, the fault code definition would be “ECT voltage out of range high.” Although not shown, for the purposes of discussion we will assume the reference voltage (designated as VREF in the diagram), is 5 volts. By researching our reference information, we learn that the code setting criteria for a low voltage fault code is set when the PCM internal voltmeter senses less than 0.5 volts, and the code setting criteria for a high voltage fault code is 4.5 volts or greater.
Knowing what the parameters are for setting that code, (that is, we know the PCM is receiving an input voltage in excess of 4.5Volts) what is our next step? We need to ask ourselves, “Is the PCM really receiving an out-of- range input from the ECT sensor that is greater than 4.5 volts, or does the PCM just “think” that the input is out of range? Is the internal voltmeter really measuring greater than 4.5 volts at the point in the circuit where the internal voltmeter is tapped?”
What are the possibilities for that code to set? Think this through. It could be a bad sensor, or it could be a faulty PCM (either an internal voltmeter concern, or a PCM processing issue). It might also be a wiring problem, which in this case would need to be either excessive voltage drop (i. e. high resistance), or an open, in the VREF circuit between the PCM internal voltmeter and the sensor, or excessive voltage drop (again, high resistance), or an opening in the SIG RTN circuit between the sensor and the PCM. Finally, it may be an issue with the PCM power supply circuit or ground circuit.
If you were using a pinpoint test, at some point it would probably tell you to connect a breakout box to take some voltage readings. Do we really want to hassle with that?
Using the “Opposite Code Inducement” method we can come up with a quick and easy way of almost completely eliminating the use of a breakout box and pinpoint tests. So, getting back to the above example, we have a high voltage code. What can we do, as a technician, to induce the opposite code? We want to make the voltage at the internal voltmeter drop below 0.5 volts — remember, we have determined through our research that the low voltage code setting criteria was a voltage less than 0.5 volts. How can we do this?
In order to induce the opposite code for this example, we would merely unplug the sensor and connect a jumper wire between the VREF and SIG RTN circuits. Then, go back with your scan tool and again run your code retrieval. If the code now retrieved has changed to the opposite code, what do we know? We have effectively verified our wiring circuits and our PCM internal voltmeter and PCM processing functions, so we know that in this particular example, the sensor is the problem.
But what if the sensor isn’t the problem and we don’t retrieve the opposite code? Then we would simply plug the sensor back in, power up the circuits and with our digital multimeter back probe at the sensor connector to check for the correct voltage measurements on the VREF and SIG RTN circuits. If we find circuit integrity on both circuits, we know we have a PCM issue. Finding the correct voltage measurements on both of these circuits also rules out a PCM power supply and ground circuit problem. If the correct measurements are not found, then it is a matter of voltage drop testing the circuits involved to determine the problem.
Conversely, if we originally retrieved a fault code for an input voltage that was out of range low, we could induce the opposite code by simply unplugging the sensor. This should make the measured voltage inside the PCM rise to greater than 4.5volts, and induce the opposite code. If the code does in fact change to the opposite code, we know again, the sensor is at fault. However, if the code doesn’t change, we once again have wiring or PCM issues to consider. In this particular instance, the types of wiring issues to consider are VREF shorted to ground, a
wire to wire short between the VREF and SIG RTN circuits, or again, a PCM power supply or ground circuit issue. Again, if we verify the integrity of the circuits involved, the only item remaining to replace is the PCM.
Read and review this procedure a few times and let it sink in. It’s really quite simple when you give it some thought. Practice it on some “known good vehicles” so that you will be well acquainted with the procedure when the time comes to put it to practical use on a vehicle with a real problem.
It is important to mention at this point that the examples I have cited above are used solely for the purposes of explaining the diagnostic method of “Opposite Code Inducement” and may not apply to any one particular diagnostic scenario. Make certain that the appropriate manufacturer’s service manual literature is consulted to make absolutely certain that all of the correct information is available for the particular repair scenario being addressed.
In a future column, I will discuss using OCI to diagnose fault code situations on three wire sensor circuits.
Now you’re dangerous …